Answers are grounded in this paper and cite their sources.
Demonstrates an advanced low-power method improving stress detection accuracy in bolts, suggesting its utility in engineering applications.
Traditional ultrasonic bolt stress measurement is hindered by high power consumption. Lowering excitation voltage reduces power but degrades signal-to-noise ratio (SNR), compromising accuracy. This paper proposes a synergistic algorithm combining Empirical Mode Decomposition (EMD) with Adaptive Threshold Wavelet Denoising (ATWD). The method preserves transient features by reconstructing high-frequency components via EMD, then suppresses noise by precisely processing low-frequency components using ATWD. Finally, cross-correlation estimates ultrasonic delay. Evaluated at excitation voltages from 12 V to 0.5 V, the EMD-ATWD method maintains measurement errors below 10% even at 0.5 V, improving accuracy by over 48% compared to conventional Finite Impulse Response (FIR) and Threshold Wavelet Denoising (WTD) methods, while enhancing key echo waveform fidelity by over 35%. This method provides a reliable low-power bolt stress monitoring idea for engineering applications.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.