Key result
Flexible tonoarteriography and ECG sensors show stronger correlation with reference BP than ECG and PPG.
Why the study?
Does a TAG-based body sensor network provide better correlation with reference continuous blood pressure compared to ECG and PPG sensors?
Does a TAG-based body sensor network provide better correlation with reference continuous blood pressure compared to ECG and PPG sensors?
A flexible tonoarteriography-based body sensor network may offer improved accuracy for continuous, cuffless blood pressure measurement compared to traditional PPG-based methods.
Answers are grounded in this paper and cite their sources.
May support TAG sensors for PTT-based BP monitoring in animals; leaves open human translation and clinical adoption.
Recent advances in unobtrusive sensing technology, especially those in flexible, stretchable, and printable sensing, have given rise to various novel signal acquisition modalities, such as stretchable epidermal electrocardiography (ECG), organic photoplethysmography (PPG), and flexible tonoarteriography (TAG) which is the cuffless and continuous recording of arterial blood pressure (BP). With the fast development of wearable computing and wireless communication technologies, all these modalities can be integrated into a body sensor network (BSN) for remote physiological multi-parameter monitoring. In this paper, we propose a TAG-based BSN for unobtrusive BP measurement with possible automatic cuffless BP calibration, and our efforts focus on the effect of posture change on the various pulse transit time (PTT) calculated from different BSN nodes consisting of TAG, ECG, and PPG sensors. Specifically, correlations of different PTTs with reference continuous BP at different postures are examined. The results of this study demonstrate that the PTT from ECG and TAG sensors has higher correlation with the reference BP as compared to that from ECG and PPG sensors, which suggests that flexible TAG sensor may potentially be utilized not only for cuffless calibration, but also as an alternative node in the BSN for continuous, cuffless BP measurement with better accuracy.
No takes yet. Share an insight, caveat, or question.
Ding et al. (2015) studied this question. The PTT from flexible tonoarteriography and ECG sensors showed higher correlation with reference BP compared to PTT from ECG and photoplethysmography sensors.