Center of Pressure Measurement Sensing System for Dynamic Biomechanical Signal Acquisition and Its Self-Calibration

View Full Paper
NLNi LiJZJianrui ZhangKZKeer Zhang

Key Points

  • This research aims to develop a dynamic sensing system for accurate Center of Pressure measurement in bipedal robots.
  • Developed a foot-mounted measurement system for CoP acquisition.
  • Implemented an online self-calibration method during locomotion.
  • Used sliding window optimization for updating sensor parameters.
  • Conducted walking experiments using a NAO-V5 robotic platform.
  • Achieved improved consistency in pressure measurements during trials compared to offline calibration.
  • Reconstructed vertical ground reaction force signals from load-cell data, identifying limitations in signal quality.
  • Demonstrated practical application of low-cost hardware for dynamic sensor calibration.

Abstract

The development of highly dynamic bipedal robots demands sensing capable of capturing key contact-related signals in real time, particularly the Center of Pressure (CoP). CoP is fundamental for locomotion control and state estimation and is also of interest in biomedical applications such as gait analysis and lower-limb assistive devices. To enable reliable CoP acquisition under dynamic walking, this paper presents a foot-mounted measurement system and an online self-calibration method that adapts sensor scale and bias parameters during locomotion using both external foot sensors and the robot’s proprioceptive measurements. We demonstrate an online self-calibration pipeline that updates foot-sensor scale and bias parameters during a walking experiment on a NAO-V5 platform using a sliding window optimization. The reported results indicate improved within-trial consistency relative to an offline-calibrated reference baseline under the tested walking conditions. In addition, the framework reconstructs a digitized estimate of the vertical ground reaction force (vGRF) from load-cell readings; due to ADC quantization and the discrete offline calibration dataset, the vGRF signal may exhibit stepwise behavior and should be interpreted as a reconstructed (digitized) quantity rather than laboratory-grade continuous force metrology. Overall, the proposed sensing-and-calibration pipeline offers a practical solution for dynamic CoP acquisition with low-cost hardware.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Li et al. (2026) studied this question.

synapsesocial.com/papers/6980fe8ac1c9540dea810a2fhttps://doi.org/10.3390/s26030910
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Fabrication of four-point biped robot foot module based on contact-resistance force sensor and its evaluation2011 · 10 citations
  2. 2iCub: the design and realization of an open humanoid platform for cognitive and neuroscience research2007 · 279 citations
  3. 3Push Recovery by stepping for humanoid robots with force controlled joints2010 · 205 citations
  4. 4Center of Pressure Control for Balancing Humanoid Dance Robot Using Load Cell Sensor, Kalman Filter and PID Controller2023 · 7 citations
  5. 5Dynamic Torso Compliance Control for Standing and Walking Balance of Position-Controlled Humanoid Robots2021 · 51 citations