Key result
Non-expert semi-automated thoracic aorta MRA achieves high agreement with expert measurements.
Why the study?
Does non-expert centerline semi-automatic measurement (CSAM) of the thoracic aorta on CE-MRA provide comparable reproducibility to expert double oblique multiplanar reformation?
Observational (n=68)
Does non-expert centerline semi-automatic measurement (CSAM) of the thoracic aorta on CE-MRA provide comparable reproducibility to expert double oblique multiplanar reformation?
Semi-automated centerline measurements of the thoracic aorta by non-experts on CE-MRA are feasible and highly reproducible compared to expert manual measurements, potentially improving clinical workflow.
BACKGROUND: Centerline semi-automatic measurements (CSAM) of the thoracic aorta have been shown to reduce interobserver variability of diameter measurements. The purpose of this study is to demonstrate the feasibility and efficiency of non-expert CSAM using contrast-enhanced magnetic resonance angiography (CE-MRA) versus double oblique (DO) multiplanar reformation (MPR) measurements obtained by experts, and to assess CSAM failure rate in subjects with and without thoracic aortic disease (TAD). METHODS: Image-based navigator (iNAV) and variable density sampling with Cartesian spiral-like trajectories (VD-CASPR) framework for non-rigid motion correction and image acceleration were utilized for inversion recovery gradient echo MRA. Thoracic MRA was obtained in 41 TAD subjects and 27 normals and independently analyzed by expert cardiologists for DO MPR measurements; one cardiovascular imaging fellow (CSAM1) obtained CSAM in all subjects; another (CSAM2) obtained CSAM in TAD patients. Nine prior MRA exams were analyzed for CSAM in seven subjects with stable aneurysms. Post-processing efficiency and intra/interobserver agreement were assessed at the sinus of Valsalva (SOV), sinotubular junction (STJ), and ascending aorta (AAO) using intra/interclass correlation coefficients. Contour failures were graded on a four-point scale: 1- failure of ≤25% vessel circumference; 2- 26-50% circumference failure; 3- 51-75% circumference failure; 4- >75% failure. RESULTS: CSAM1 failure rate was 13% and 14% in the TAD and normal cohorts, respectively (p = 0.78). CSAM 2 failure rate was 2% in the TAD cohort. Intraobserver agreement was excellent for both methods. SOV interobserver agreement with DO MPR performed the worst, with the lowest interclass correlation (ICC) for SOV major (vs physician 1) in the normal cohort (ICC = .69). Otherwise, agreement with DO MPR was near excellent. Major diameter interobserver agreement was excellent in the TAD cohort. Efficiency was highest for CSAM2. In stable TAD, baseline and follow-up major diameter measurements were not significantly different. CONCLUSION: Non-expert MRA CSAM is feasible with excellent intraobserver and excellent to near excellent interobserver agreement at the STJ and AAO levels compared to expert DO MPR. CSAM failure rates varied significantly between non-expert readers; inter-study CSAM were overall precise.
No takes yet. Share an insight, caveat, or question.
Craft et al. (2026) conducted an observational in Thoracic aortic disease (n=68). Centerline semi-automatic measurements (CSAM) vs. Double oblique (DO) multiplanar reformation (MPR) was evaluated on CSAM1 failure rate in thoracic aortic disease vs normal cohorts (p=0.78). Non-expert centerline semi-automatic measurements of the thoracic aorta were feasible, with a 13% to 14% failure rate and excellent agreement compared to expert double oblique measurements.