February 2, 2026Journal of Orthopaedic Diseases and Traumatology0 citationsOpen Access

A Clinical Outcome-based Prospective Study with Fixed Versus Adjustable Femoral Loop Suspension Device in Arthroscopic Anterior Cruciate Ligament Reconstruction

View Full Paper
ASAruddha SarkarDepartment of Health & Family WelfareBSBiswarup SenSant Parmanand HospitalRERaju EaswaranMax Super Speciality Hospital

Key Points

  • This study aims to compare the clinical outcomes of fixed-loop and adjustable-loop suspension devices used in ACL reconstruction.
  • Prospective randomized study design
  • Included 16 patients in each group for comparison
  • Evaluated clinical outcomes using IKDC score and knee instability tests preoperatively and at 6 months postoperatively
  • Conducted instability tests including anterior drawer, pivot shift, and Lachman test
  • Mean IKDC score at 6 months for fixed loop was 72.2% and for adjustable loop was 70.3%
  • Statistical analysis showed no significant difference in outcomes between groups (P > 0.05)
  • Significant improvement observed in all knee instability tests postoperatively
  • Negative results in anterior drawer and pivot shift tests for all patients; only one positive Lachman test in each group

Abstract

Introduction: Femoral suspension devices are widely used in arthroscopic reconstruction of anterior cruciate ligament (ACL) tears. They can be fixed or adjustable-loop devices. Only a few bio-mechanical studies comparing the efficacy of these two devices are available in the literature. Our study aims to compare clinical outcomes between the fixed-loop device (Group I) and the adjustable-loop device (Group II). Materials and Methods: This was a prospective randomized study. Sixteen patients were included in each group. One patient in each group was lost to follow-up. Assessment of clinical outcome was done with the International Knee Documentation Committee (IKDC) score and knee instability tests. Patient evaluation was performed preoperatively and 6 months postoperatively. Results: The mean postoperative IKDC score for the fixed loop group at 6 months was 72.2% (standard deviation SD =4.8), and for the adjustable loop was 70.3% (SD = 5.2). The difference in the outcomes was statistically insignificant ( P > 0.05). Postoperatively, significant improvement was seen in all three instability tests. Anterior drawer and pivot shift tests were negative in all the patients in both groups. One patient in each group had Grade 1 positive Lachman test. Hence, no significant difference was found in terms of instability and clinical tests between patients in either group. Conclusion: ACL reconstruction with fixed- and adjustable-loop suspensory devices for graft fixation gives equivalent and satisfactory clinical results.