This research introduces a novel ultrasonic method to detect small foreign object debris in carbon fiber composites, suggesting improved inspection techniques.
This study investigates ultrasonic wave propagation in carbon fiber reinforced polymer (CFRP) composites containing foreign object debris (FOD) by introducing a novel method to characterize the depth and size of FOD, from a single captured waveform generated by an out-of-focus spherically focused transducer. Current methods of inspection utilize a raster approach to both detect and quantify FOD, which is limited to identifying FOD smaller than 4 mm. The method introduced in the present paper allows for a single point scan to detect and quantify FOD, as small as 0.5 mm, with the highest error in the depth estimation being less than 8%. This paper presents experimental testing to inform a finite element analysis of a full waveform simulation of an immersion tank inspection environment and compares waveforms between testing and simulation. A transient pressure acoustic model is developed in the COMSOL Multiphysics environment to simulate wave propagations. Simulation results provide waveform reflection and transmission at material interfaces, which will occur when there is an acoustic mismatch between materials. The transmitted ultrasonic wave is partially reflected toward the transducer upon encountering material interfaces between the water, CFRP laminate, and the FOD. Simulation results show that the acoustic profile and pressure of the reflected wave captured by the transducer allows an accurate identification of FOD depth and size within the composite structure, suggesting an alternative method of inspection to quantify FOD characteristics faster than through conventional approaches. Results show an increase in captured signal pressure of over 125% between the 0.5 mm FOD and the 1 mm FOD located on the mid-plane of the laminate, and 500% between the same 0.5 mm FOD and 1 mm FOD placed near the front wall. These results suggest the potential sensitivity limits for physical component. This work demonstrates that small FOD, which are often difficult to resolve and quantify under conventional raster-based inspection, can be reliably identified by intentionally positioning the specimen within the defocused region of a spherically focused transducer. Results are presented to correlate the reflected acoustic pressure amplitude to defect depth, transducer–specimen distance, and FOD size, providing an approach to quantitatively discriminate small defects that would otherwise produce ambiguous signals.
No takes yet. Share an insight, caveat, or question.
Hassanpoor et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: