Key result
Left atrial aperture ≤1.8 mm linked to ~11-fold greater guidewire failure risk during PFO closure.
Why the study?
Transcatheter closure of patent foramen ovale is effective, but guidewire passage failure remains a procedural challenge.
What are the risk factors for guidewire failure to pass through the foramen ovale in PFO patients during interventional closure?
Observational (n=83)
What are the risk factors for guidewire failure to pass through the foramen ovale in PFO patients during interventional closure?
Left atrial aperture ≤1.8 mm, right-to-left shunt grade, and surgical team experience are key predictors of guidewire passage failure during PFO closure, which can be accurately assessed using a novel predictive model.
Small left atrial aperture may predict guidewire failure in PFO closure; leaves open prospective validation of the model.
Patent foramen ovale (PFO) is a common congenital cardiac anomaly. Transcatheter closure is effective, but guidewire passage failure remains a challenge. We aimed to identify risk factors and develop a predictive model for procedural failure. This retrospective study included 83 PFO patients (October 2021–May 2024) undergoing interventional closure, divided into success (n = 52) and failure (n = 31) groups. Multivariate logistic regression analyzed risk factors, and a nomogram was developed. Model calibration was assessed using the Hosmer–Lemeshow test and calibration curves, while discriminative ability was evaluated via receiver operating characteristic analysis. Predictive accuracy was validated through 5-fold cross-validation, and clinical utility was examined using decision curve analysis and clinical impact curve. Left atrial aperture ≤1.8 mm was a significant risk factor for failure (odds ratio [OR] = 10.691, P < .05), while contrast transthoracic echocardiography-determined right-to-left shunt grade II (OR = 0.147) and III (OR = 0.056), and surgical team experience >3 years (OR = 0.077) were protective (all P < .05). The model was well calibrated (χ² = 4.002, P = .857), and the area under receiver operating characteristic curve was 0.913, indicating medium to strong predictive ability. The mean area under the curve for 5-fold cross-validation was 0.878, and decision curve analysis confirmed clinical utility at threshold probabilities of 0.01 to 0.85. The clinical impact curve demonstrated high consistency between predicted and actual outcomes when the threshold probability exceeded 60%. The model has good calibration, accuracy, distinguishing power, and clinical applicability, and provides a valuable tool for preoperative risk assessment of PFO occlusion.
No takes yet. Share an insight, caveat, or question.
Zhou et al. (2026) conducted an observational in Patent foramen ovale (PFO) (n=83). Interventional closure was evaluated on Guidewire passage failure (OR 10.691, p=<.05). Left atrial aperture ≤1.8 mm significantly increased the risk of guidewire passage failure during PFO closure (OR 10.691, P<0.05), and a developed predictive model showed strong accuracy (AUC 0.913).