Analysis quantifies operational impacts of gas-lock on Electrical Submersible Pump performance, indicating critical venting needs.
This study employs a validated dynamic multiphase flow model to quantify the severe operational impacts of impaired annulus gas venting on Electrical Submersible Pump (ESP) performance. Utilizing high-frequency field data from a documented gas-lock incident-initiated by the inadvertent closure of a valve-the analysis demonstrates how a surge in the pump intake gas flow rate (from 0.2 to 0.4 MMSCFD) triggers a cascade of system failures. These include a severe oscillatory decline in the liquid flow rate of up to 300 STBD, leading to an overall production loss of 23%. The incident further induced significant system instability, manifested as amperage fluctuations between 40 and 58 A, Pump Intake Pressure (PIP) oscillations with an amplitude of ± 30 psi, and impaired motor cooling. The primary contribution of this work is a detailed causal analysis and dynamic quantification of the gas-lock progression, establishing a benchmark for its severity. These findings underscore the critical, non-negotiable requirement for proper annulus venting in both ESP design and operational procedures to prevent catastrophic production losses and equipment damage.
No takes yet. Share an insight, caveat, or question.
Bakri et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: