Automated pre-processing enhances Raman spectroscopy analysis in tumor tissues, suggesting improved accuracy in radiation response monitoring.
Raman spectroscopy (RS) is a label-free, non-destructive optical modality that provides a detailed profile of the molecular composition of a sample. There is growing interest in the clinical application of RS to characterize biomolecular signatures associated with radiotherapy response in tumor cells and tissues. A critical step before analyzing Raman data consists of performing spectral pre-processing to increase the quality of the measurements. Spectral pre-processing comprises baseline subtraction, signal smoothing, cosmic ray (CR) correction, and removal of poor-quality measurements. Herein, we present a convolutional autoencoder (AE) for single-step, automated pre-processing of Raman spectra obtained from tumor cells and tumor tissue. We trained two separate models using the same proposed architecture, one for eliminating spectral artifacts from preclinical single-cell line and xenografted tissue spectra exposed to single-fraction radiation, and the other for correcting clinical prostate tumor biopsy spectra collected from patients receiving high-dose-rate brachytherapy (HDR-BT). The autoencoder demonstrated fast, excellent performance in removing baseline, noise, and CRs. For the preclinical data, the model obtained a root mean squared error (RMSE), and a percentage root mean squared difference (PRD) of 7.1 × 10 −5 and 3.1%, respectively, between the AE-corrected spectra and their corresponding target data (pre-processed by our current baseline-removal algorithm). Also, the autoencoder successfully removed 94.0% of CRs from the spectra. For the clinical biopsy data, the AE achieved an RMSE and a PRD of 8.1 × 10 −5 and 3.7%, respectively, and a CR removal rate of 90.2%. Overall, the AE corrected approximately 11 000 spectra within 2.4 s without the need of a GPU. Furthermore, comparative supervised learning-based post-processing data analyses were performed separately on the spectra pre-processed by the autoencoder versus the target data, and we show consistency in the biochemical radiation response profiles extracted. Finally, the AE architecture was leveraged to train a reconstruction AE to facilitate semi-automated identification of poor-quality prostate biopsy spectra, and we demonstrate 96.4% agreement between AE and manually removed outliers. These results support the development of a deep learning framework for efficient, automated pre-processing of tumor cell and tissue Raman spectra collected for radiation response monitoring studies.
No takes yet. Share an insight, caveat, or question.
Fuentes et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: