PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 5, 2026Journal of Eye Movement Research1 citationsOpen Access

Analysis of Saccade Characteristics During Fusional Vergence Tests in Normal Binocular Vision Participants

View Full Paper
CRCristina Rovira-GayUniversitat Politècnica de CatalunyaCMClara Duran i MestreIndiana University BloomingtonMAMarc Argilés

Key Points

  • The aim is to analyze and compare saccade measurements during positive and negative fusional vergence tests.
  • Measured saccades during positive fusional vergence (PFV) and negative fusional vergence (NFV) tests.
  • Used an Eyelink 1000 Plus to record eye movements in a haploscopic setup.
  • Determined break and recovery points offline, detecting saccades with a velocity-threshold-based method.
  • Detected a total of 13,103 saccades during PFV and 14,381 during NFV.
  • Found significant differences in saccade amplitudes during fusion (0.73 degrees) versus diplopia (2.10 degrees).
  • Saccade direction distributions during PFV and NFV testing were statistically different.

Abstract

The purpose of the study was to analyze, characterize, and compare the measurements of saccades that occurred during the positive and negative fusional vergence test (PFV and NFV, respectively) as a function of the disparity vergence demand. Thirty-four participants’ PFV and NFV amplitudes were measured in a haploscopic setup, recording eye movements with an Eyelink 1000 Plus (SR Research). The visual stimulus was a column of letters. Break and recovery points were determined objectively offline, and saccades were detected with a velocity-threshold-based method. A total of 13,103 and 14,381 saccades were detected during the measurement of the PFV and NFV ranges, respectively. Saccades followed the main sequence (ρ = 0.97, p < 0.001). The distributions of saccadic amplitudes during PFV and NFV differed significantly (U = 4.28, p < 0.001). The amplitude of saccades that occurred while fusion was maintained (median (IQR) 0.73 (0.92) deg) was significantly smaller than that of saccades during diplopia (2.10 (3.90) deg) (U = −75.63, p < 0.001). The distributions of saccade direction during the measurement of PFV and NFV amplitudes were statistically significantly different (p < 0.01). These findings contribute to a better understanding of how the visual system adjusts saccades in response to different disparity vergence demand during fusional vergence amplitudes evaluation.