Key result
Handheld FHR monitors detect abnormal patterns with 92% sensitivity versus standard CTG.
Why the study?
Standard cardiotocography is often unavailable in low-resource primary care settings, and the diagnostic accuracy of handheld Doppler devices in routine practice requires rigorous, context-specific validation.
Does a handheld Doppler fetal heart rate monitor accurately detect abnormal fetal heart rate patterns compared to standard cardiotocography in pregnant women in their third trimester?
Cross-Sectional (n=350)
Single-blind
Test order randomized
Yes
Does a handheld Doppler fetal heart rate monitor accurately detect abnormal fetal heart rate patterns compared to standard cardiotocography in pregnant women in their third trimester?
A handheld Doppler device demonstrates good diagnostic accuracy compared to standard CTG for third-trimester fetal heart rate monitoring, offering a pragmatic and reliable screening tool for low-resource primary care settings.
Answers are grounded in this paper and cite their sources.
May aid low-resource fetal monitoring; leaves open prospective validation before adoption.
**Abstract** In low-resource primary care settings, access to standard cardiotocography (CTG) for antenatal fetal surveillance is often unavailable. Handheld Doppler devices present a pragmatic alternative, but their diagnostic accuracy in routine practice requires rigorous, context-specific validation. This study aimed to evaluate the diagnostic accuracy of a handheld fetal heart rate (FHR) monitor against standard CTG for identifying normal and abnormal FHR patterns during the third trimester in Nigerian primary healthcare centres. A cross-sectional diagnostic accuracy study was conducted across multiple primary health centres in Enugu State, Nigeria. A consecutive sample of 350 pregnant women in their third trimester underwent simultaneous FHR monitoring using a handheld Doppler device and a standard CTG machine. All assessments were performed by trained midwives. CTG traces were interpreted by a blinded obstetrician as the reference standard. Sensitivity, specificity, positive predictive value (PPV), and agreement statistics were calculated. Compared to CTG, the handheld device demonstrated a sensitivity of 92% and a specificity of 86% for detecting abnormal FHR patterns, with a PPV of 78%. The mean difference in FHR measurement between devices was 3.2 beats per minute, indicating good agreement. The handheld FHR monitor showed good diagnostic accuracy for routine antenatal assessment in a primary care setting. It represents a clinically useful tool for initial screening, potentially improving access to basic fetal surveillance. Integration into routine care is supported, with recommendations for healthcare worker training and a protocol whereby abnormal readings prompt referral for confirmatory CTG. **Keywords:** fetal heart rate monitoring, cardiotocography, diagnostic accuracy, primary health care, Nigeria, antenatal care, handheld Doppler
No takes yet. Share an insight, caveat, or question.
Okonkwo et al. (2020) conducted a cross-sectional in Pregnancy (third trimester) (n=350). Handheld Doppler fetal heart rate (FHR) monitor vs. Standard cardiotocography (CTG) was evaluated on Detection of abnormal FHR patterns (Sensitivity 92%, Specificity 86%). The handheld fetal heart rate monitor demonstrated a sensitivity of 92% and a specificity of 86% for detecting abnormal patterns compared to standard cardiotocography.