Key result
Alterra/SAPIEN 3 transcatheter pulmonary valve maintains ~97% freedom from reintervention at three years.
Why the study?
Long-term outcomes needed to be evaluated for patients with a dysfunctional RVOT and PR treated with the Alterra Adaptive Prestent and 29 mm SAPIEN 3 THV.
Does transcatheter pulmonary valve implantation with the Alterra Adaptive Prestent and SAPIEN 3 THV improve THV dysfunction and reduce pulmonary regurgitation in patients with dysfunctional RVOT?
Does transcatheter pulmonary valve implantation with the Alterra Adaptive Prestent and SAPIEN 3 THV improve THV dysfunction and reduce pulmonary regurgitation in patients with dysfunctional RVOT?
The Alterra Adaptive Prestent with the SAPIEN 3 THV demonstrates excellent 3-year durability, safety, and efficacy in reducing pulmonary regurgitation for patients with dysfunctional RVOT.
Supports durability of Alterra-SAPIEN 3 in dysfunctional RVOT; extends short-term data but leaves open need for RCTs.
BACKGROUND: The Alterra Adaptive Prestent provides a landing zone for implantation of the 29 mm SAPIEN 3 transcatheter heart valve (THV) in patients with a dysfunctional right ventricular outflow tract (RVOT) to treat pulmonary regurgitation (PR). Here, we report 3-year outcomes from a pooled analysis of patients who underwent Alterra/SAPIEN 3 THV implantation enrolled in the ALTERRA pivotal trial, Continued Access Protocol, and Pulmonic Delivery System Registry. METHODS: This multicenter, prospective trial enrolled patients with moderate or greater PR and RVOT/pulmonary valve anatomy suitable for implantation. The nonhierarchical composite end point of THV dysfunction was examined at 6 months: RVOT/pulmonary valve reintervention, moderate or greater PR, and mean RVOT/pulmonary valve gradient ≥35 mm Hg. Individual components of the composite, as well as additional clinical and echocardiographic outcomes were examined up to 3 years. RESULTS: The Alterra/SAPIEN 3 THV system was implanted in 118 patients at 14 sites. At 6 months, THV dysfunction was 3.5% (4/113). At 3 years, 97.3% of patients in the valve implant population had freedom from reintervention, 100% of patients had a mean RVOT/pulmonary valve gradients <35 mm Hg, and 93.3% of patients had mild or lesser total PR. The Kaplan-Meier estimate of all-cause mortality was 3.5% at 3 years. There were no cases of coronary artery compression, hemopericardium, or endocarditis. CONCLUSIONS: This analysis reports the longest follow-up in the largest cohort of patients from the ALTERRA trials. The Alterra Adaptive Prestent with the SAPIEN 3 THV system has shown excellent procedural outcomes and is effective in reducing PR at 3-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03130777.
No takes yet. Share an insight, caveat, or question.
Torres et al. (2026) studied this question. At 3 years post-implantation, 97.3% of patients had freedom from reintervention, 100% had mean RVOT gradient <35 mm Hg, and 93.3% had mild or less pulmonary regurgitation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: