PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 11, 2026Analytical Chemistry0 citations

A Robust Nonfouling Biosensor Based on an Engineered Multifunctional Monocyclic Peptide for Electrochemical Detection of Biomarkers in Human Blood

View Full Paper
BZBaoping ZhuRHRui HanBLBin Liu

Key Points

  • The aim is to develop a biosensor using a multifunctional monocyclic peptide to detect HER2 without interference from proteins or enzymes.
  • Developed an electrochemical biosensor using a multifunctional monocyclic peptide (MMCP).
  • Designed the MMCP to resist biofouling and enzymatic degradation while recognizing HER2.
  • Evaluated the biosensor's performance in complex biological environments, including human blood and compared with ELISA.
  • Achieved a linear detection range for HER2 from 1.0 pg mL-1 to 1.0 μg mL-1.
  • The limit of detection for the biosensor was 0.35 pg mL-1.
  • Biosensor results aligned closely with those obtained from ELISA in clinical blood samples.

Abstract

Electrochemical biosensors are susceptible to interference from biofouling of nonspecific proteins and the proteolytic hydrolysis of immobilized biomolecules by natural enzymes in complex biological media like blood. Therefore, enhancing the antifouling capability and the antienzymatic degradation ability is crucial for biosensors to perform in practical clinical samples. Herein, an electrochemical biosensing platform based on a multifunctional monocyclic peptide (MMCP) was developed, and the MMCP was designed with antifouling and antienzymatic degradation properties and the specific target (human epidermal growth factor receptor 2, HER2) recognition capability. The MMCP contains an antifouling part formed through covalent cyclization of a linear antifouling sequence (ECHHHHKHHHHCE) and a recognition d-peptide sequence (refffly) that can specifically recognize and bind HER2. Due to the cyclic structure and the adoption of d-amino acids, the MMCP can effectively resist the enzymatic degradation and shows significantly enhanced stability. The MMCP-based biosensor demonstrated outstanding antifouling performance and hydrolysis resistance properties in complex biological environments, and it was capable of sensitively detecting HER2 with a linear range of 1.0 pg mL-1 to 1.0 μg mL-1 and a low limit of detection of 0.35 pg mL-1. Additionally, the assay results of the biosensor for HER2 in clinical blood samples were consistent with those obtained from the enzyme-linked immunosorbent assay (ELISA). The strategy of designing a specific peptide reported herein offers an effective way to construct robust biosensors for biomarker detection in complicated clinical samples.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zhu et al. (2026) studied this question.

synapsesocial.com/papers/698c1c73267fb587c655ee8fhttps://doi.org/10.1021/acs.analchem.5c07842
Ask AI
Helpful
Bookmark
Share
View Full Paper