Describes diaphragm ultrasonography during breathing tests, revealing insights into muscle movement.
This study aimed to describe diaphragm ultrasonography (DU) during mouth occlusion pressure (P0.1) and maximal inspiratory pressure (MIP) in healthy participants. Four participants performed: (i) neurophysiological tests and then (ii) simultaneous DU with P0.1 and MIP. Diaphragm excursion was 2.37 cm (median) during tidal volume of 0.74 L. Additionally, a median diaphragm excursion of 1.25 cm was associated with a median P0.1 of 1.39 cm H 2 O, while a median diaphragm excursion of 3.10 cm was associated with a median MIP of 125.88 cm H 2 O. DU showed a hold‐back movement during P0.1 and a movement plateau during MIP, providing novel insights into the diaphragm movement, with potential clinical practice implications.
No takes yet. Share an insight, caveat, or question.
Leote et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: