PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 26, 2026Sensors0 citationsOpen Access

Design and Calibration of a Single-Lens Telecentric Four-Camera Array Based on Planar Mirrors and Its Application in Strain Measurement

View Full Paper
XZXu ZhangGCGuo Chen

Key Points

  • The research aims to design a telecentric camera array for improved strain measurement in aircraft hydraulic pipelines.
  • Developed a virtual telecentric camera system using a single lens and planar mirrors.
  • Established a simulation framework to compare telecentric and pinhole projection models.
  • Created a calibration strategy for non-overlapping telecentric fields of view.
  • Conducted experimental tests on hydraulic pipeline installations.
  • Demonstrated lower reprojection errors with the telecentric system compared to traditional pinhole models.
  • Achieved high concordance with strain gauge data in experiments.
  • Validated the effectiveness of the system in minimizing parallax errors during measurements.

Abstract

As the primary power transmission conduits, aircraft hydraulic pipelines are critical for actuating flight control surfaces and landing gear systems. Accurate in situ strain evaluation of these pipelines is essential, as installation-induced pre-loads directly compromise fatigue life and sealing performance, threatening overall system reliability. However, such evaluation is frequently hindered by the perspective distortions and limited depth of field inherent in conventional imaging systems. To overcome these metrological limitations, this study presents a novel virtual telecentric camera array system designed for high-precision, non-contact strain measurement. Unlike traditional pinhole models, the proposed system leverages a catadioptric setup with planar mirrors to create a virtual four-eye telecentric array from a single physical lens, ensuring constant magnification within the depth of field. A comprehensive simulation framework was established to rigorously compare the reprojection errors and scale accuracies between telecentric and pinhole projection models, quantitatively demonstrating the superior stability of the telecentric approach. Furthermore, a dedicated calibration strategy for non-overlapping telecentric fields of view was developed and validated. Experimental results from pipeline installation tests indicate a high concordance with strain gauge data, confirming that the proposed telecentric system effectively mitigates parallax errors and provides a robust solution for static and quasi-static micro-scale deformation monitoring in complex assembly environments.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zhang et al. (2026) studied this question.

synapsesocial.com/papers/699fe41d95ddcd3a253e84fehttps://doi.org/10.3390/s26051427
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Improved ultrasonic absolute stress measurement based on optimized wavelet transform and cross-correlation algorithm2025 · 11 citations
  2. 2Digital image correlation for surface deformation measurement: historical developments, recent advances and future goals2018 · 885 citations
  3. 3Experimental Verification of Effect of Adhesive Layer Thickness Used for Strain Gauge Mounting2015 · 8 citations
  4. 4Calibration of binocular cameras with non-overlapping fields of view based on planar mirrors2021 · 4 citations
  5. 5Accurate calibration of a multi-camera system based on flat refractive geometry2017 · 25 citations