Bond–Slip Performance of GFRP Rebars in Concrete Under Alkaline and Thermal Conditioning

View Full Paper
FNFrancesca NerilliHAHadi AhmadiSIStefania Imperatore

Key Points

  • The aim is to understand the bond-slip performance of GFRP bars in concrete when subjected to alkaline conditions and varying temperatures.
  • Compiled a database of 84 pull-out tests from existing literature.
  • Conducted additional pull-out tests on sand-coated GFRP bars in alkaline solutions at different temperatures.
  • Performed an analytical formulation to evaluate shear stress and slip distributions.
  • Average bond strength reduction of approximately 28% in ambient temperature and 32% at 60 °C.
  • Identified significant bond degradation associated with surface treatment.
  • Observed variability in existing results regarding bond performance in high-pH conditions.

Abstract

This study investigates the bond–slip behavior of glass fiber-reinforced polymer (GFRP) bars embedded in concrete and exposed to alkaline environments at different temperatures. Although GFRP reinforcement is increasingly adopted for its corrosion resistance, the long-term bond performance of the bar–concrete interface in high-pH conditions is still not fully understood. To help close this gap, a comprehensive database of 84 pull-out tests from the literature was assembled, focusing on three key parameters: bar surface configuration, exposure duration, and conditioning temperature. The comparative analysis highlights the dominant role of surface treatment in bond degradation and reveals substantial variability across existing results. To complement the literature review, additional pull-out tests were carried out on sand-coated GFRP bars conditioned in an alkaline solution (pH = 12) for 1.5 months at ambient temperature and at 60 °C. These tests showed average reductions in bond strength of approximately 28% and 32%, respectively, compared with unconditioned specimens, together with marked changes in the post-peak portion of the bond–slip response. An analytical formulation was also applied, not as a novel bond–slip law but as a consistent mechanical framework to interpret durability-induced degradation effects, to describe the local interface shear stress–slip law, and to assess the resulting stress and slip distributions along the bonded length. Overall, the combined experimental and analytical findings emphasize the need to account for environmentally induced degradation when evaluating durability and defining design criteria for GFRP-reinforced concrete structures.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Nerilli et al. (2026) studied this question.

synapsesocial.com/papers/69a52dd3f1e85e5c73bf0f52https://doi.org/10.3390/jcs10030131
Ask AI
Helpful
Bookmark
Share
View Full Paper