Aptamer-Functionalized Microchannel-Gated Field-Effect Transistor Biosensor for In Vivo Detection of Dopamine

View Full Paper
YZYulan ZengLTLin TuHCHuabin Cai

Key Points

  • Dopamine detection in vivo was achieved with a sensitivity as low as 0.15 nM, indicating effective neurotransmitter monitoring.
  • The biosensor shows a linear response to dopamine concentrations from 1.00 nM to 10.0 μM, highlighting its operational range.
  • A microchannel-gated junction field-effect transistor was designed for precise dopamine detection and successful applications across mammalian models.
  • The results suggest potential for this biosensor in clinical applications, with implications for real-time monitoring of neurotransmitters.

Abstract

Field-effect transistors (FETs) have been widely applied in biosensors due to their inherent signal amplification capabilities. Glass-based microchannels offer excellent mechanical rigidity and facile surface functionalization, which have been applied in vivo. In this study, a microchannel was coupled with a junction FET (JFET) to design a sensitive biosensor for dopamine (DA, chosen as a model target) detection. A specific, negatively charged DA aptamer was immobilized on the inner wall of the microchannel as the recognition element, and the microchannel served as an extended gate connected between the electrochemical workstation and the gate of the JFET. Acting as a tunable resistor, the microchannel modulates the voltage distribution within the circuit. Since DA is positively charged, specific binding of the target to the aptamer reduces the local negative charge density of the microchannel, thereby altering the effective gate voltage. The subtle resistance shift induced by DA resulted in a change in the gate voltage, leading to a significant change in channel current. The system response exhibits a linear relationship with the logarithm of the target concentration over the range from 1.00 nM to 10.0 μM, with a detection limit as low as 0.15 nM (S/N = 3). The constructed microchannel-gated JFET biosensor exhibited high sensitivity and selectivity and was successfully applied to detect the DA concentration in the human serum and striatum of Sprague-Dawley rats, demonstrating its promising potential for trace biomolecule detection in vivo.