Answers are grounded in this paper and cite their sources.
Case report shows improved graft function and urinary flow in a kidney transplant recipient using a stent, suggesting a minimally invasive option.
Urethral strictures in kidney transplant recipients seriosly jeopardize graft function, causing urinary stasis and infections. We report a 54-year-old male kidney transplant recipient with recurrent bulbar urethral stricture, multiple failed urethrotomies, and long-term urinary devices dependency. Recurrent UTIs and graft dysfunction prompted Allium® bulbar stent placement. At 12 months, uroflowmetry improved (Qmax from 7.9 to 9 mL/s), post-void residual dropped (100 mL to 30 mL), and IPSS decreased (25 to 9). Graft function improved (creatinine 3 mg/dL). No hospitalizations occurred. This case suggests Allium® bulbar urethral stent may offer a safe, minimally invasive alternative in high-risk kidney transplant recipients.
No takes yet. Share an insight, caveat, or question.
Schiavone et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: