PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 7, 2026International Journal of Engineering Systems Modelling and Simulation0 citations

Heat transfer performance analysis of steam boilers-fin and tube heat exchangers under varying geometric dimensions

View Full Paper
SFSamson Kolawole FasogbonIFIbrahim Ademola FetugaAOAyodele Temitope Oyeniran

Key Points

  • The aim is to analyze how different geometric dimensions affect the heat transfer performance in steam boilers.
  • An analysis of heat transfer performance was conducted using COMSOL Multiphysics®.
  • Geometric parameters include tube rows, tube diameter, fin pitch, fin thickness, and fin surface area.
  • Laminar and turbulence flow models (k-epsilon and k-omega) were employed based on Reynolds-averaged Navier-Stokes equations.
  • Heat transfer stabilizes beyond six tube rows.
  • Nusselt numbers varied from 10.97 to 21.16, and effectiveness reached 0.54.
  • Key parameters for maximizing heat transfer performance are fin surface area, fin thickness, and tube diameter.

Abstract

This study analyses the heat transfer performance of fin and tube heat exchangers in steam boilers, focusing on the impact of geometrical parameters such as the number of tube rows, tube diameter, fin pitch, fin thickness, and fin surface area on thermal efficiency. Flue gases typically exit at temperatures between 298K and 523K, resulting in energy losses of 10%-30% in industrial boiler systems. The analysis employed COMSOL Multiphysics® to model flue gas flow using three approaches: laminar flow modelling and two turbulence models (k-epsilon and k-omega), all based on Reynolds-averaged Navier-Stokes equations. The k-omega model provided the best alignment with experimental data (Wang et al., 2006), enhancing heat transfer predictions. The results show that heat transfer stabilises beyond six tube rows, with Nusselt numbers ranging from 10.97 to 21.16 and effectiveness reaching 0.54. Three parameters proved critical for maximising heat transfer performance: fin surface area, fin thickness, and tube diameter. The optimal flue gas flow rate was determined to be within the range of 0.02 to 0.2 kg/s. These findings guide the design of efficient heat exchangers for waste heat recovery, minimising energy losses in industrial applications.