PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 8, 2026npj Digital Medicine2 citationsOpen Access

RoentMod: a synthetic chest X-ray modification model to identify and correct image interpretation model shortcuts

LCLauren H. CookeMJMatthias JungJBJan Michael Brendel

Key Points

  • The research aims to address shortcut learning in chest X-ray interpretation models by utilizing a synthetic image modification framework called RoentMod.
  • Developed RoentMod, a counterfactual image editing framework that modifies CXRs with synthetic pathologies while preserving anatomical features.
  • Conducted reader studies to evaluate the realism and correctness of RoentMod-generated images compared to real CXRs.
  • Incorporated RoentMod images in training to improve multi-task and foundation model performance.
  • 93% of RoentMod-generated images appeared realistic.
  • Model discrimination improved by 3–19% AUC in internal validation with RoentMod images.
  • 1–11% performance enhancement in 5 out of 6 pathologies during external testing.

Abstract

Abstract Chest radiographs (CXRs) are among the most common tests in medicine; automated interpretation may reduce radiologists’ workload and expand access. Deep learning multi-task and foundation models have shown strong CXR interpretation performance but are vulnerable to shortcut learning, where spurious correlations drive decision-making. We introduce RoentMod, a counterfactual image editing framework that generates realistic CXRs with user-specified and synthetic pathology while maintaining the original anatomical features. RoentMod combines an open-source medical image generator (RoentGen) with an image-to-image modification model without retraining. In reader studies of RoentMod-produced images, 93% appeared realistic, 89–99% correctly incorporated the specified finding, and all preserved native anatomy comparable to real follow-up CXRs. Using RoentMod, we demonstrate that state-of-the-art multi-task and foundation models frequently exploit off-target pathology as shortcuts, limiting their specificity. Incorporating RoentMod-generated counterfactual images during training mitigated this vulnerability, improving model discrimination across multiple pathologies by 3–19% AUC in internal validation and by 1–11% for 5 out of 6 tested pathologies in external testing. These findings establish RoentMod as a tool to probe and correct shortcut learning in medical AI. By enabling controlled counterfactual interventions, RoentMod enhances the robustness and interpretability of CXR interpretation models and provides a strategy to improve medical imaging models.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Cooke et al. (2026) studied this question.

synapsesocial.com/papers/69ad13cee7e9681137aa9600https://doi.org/10.1038/s41746-026-02497-6
Ask AI
Helpful
Bookmark
Share
View Full Paper