Accuracy of sixteen axial length adjusted intraocular lens power calculation formulas in long Caucasian eyes

View Full Paper
WSWiktor StopyraOVOleksiy VoytsekhivskyyAGAndrzej Grzybowski

Key Points

  • The study aims to compare the accuracy of various IOL power calculation formulas in long eyes, specifically those exceeding 26.00 mm in axial length.
  • Retrospective analysis of myopic patients with cataracts who had phacoemulsification.
  • Calculation of preoperative IOL power using six different formulas.
  • Measurement of refraction three months post-surgery.
  • Analysis of postoperative IOL power predictions from multiple formula variants.
  • Primary outcomes included RMSAE and percentage of eyes with specific prediction errors.
  • RMSAE values ranged from 0.393 (Holladay 1 NLR) to 0.803 (Haigis WK2).
  • The percentage of eyes within ±0.50 D prediction error ranged from 35.98% (Haigis WK2) to 81.1% (Holladay 1 NLR).
  • Holladay 1 NLR and SRK/T WK2 showed significantly higher accuracy compared to most formulas.
  • Haigis WK2 and Hoffer Q WK2 were among the least accurate.
  • Certain modified third-generation formulas achieved accuracy similar to new-generation formulas.

Abstract

To compare the accuracy of sixteen intraocular lens (IOL) power calculation formulas incorporating targeted adjustments or regression-based modifications of axial length (AL) in eyes longer than 26.00 mm. Retrospective observational study. The data of myopic patients with cataract who underwent uneventful phacoemulsification with in-the-bag implantation of a PARTIAL−RoF narrow IOL between January 2020 and June 2025 were reviewed. Preoperative IOL power was calculated using the IOLMaster 700 with six formulas: Barrett Universal II (BU II), Haigis, Hoffer Q, Holladay 1, Holladay 2, and SRK/T. The implanted IOL power was selected from BU II or SRK/T recommendations. Refraction was measured three months postoperatively. Postoperative IOL power predictions were generated using the following formulas or formula variants: K6, PEARL-DGS, Castrop, Eom, VRF CMAL; Holladay 1 with Wang-Koch 2 center optimization (WK2), modified Wang-Koch (MWK), non-linear regression (NLR), and Fam-adjusted method (F2); SRK/T WK2, SRK/T MWK, SRK/T F2; Holladay 2 NLR; Hoffer Q WK2; Haigis WK2; and Barrett True AL. The primary outcome measures were root mean square absolute error (RMSAE) and the percentage of eyes with prediction error (PE) within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D. One hundred sixty-four eyes with ALs ranging from 26.04 mm to 29.72 mm were included. RMSAE values across the sixteen formulas ranged from 0.393 (Holladay 1 NLR and SRK/T WK2) to 0.803 (Haigis WK2). The percentage of eyes with PE within ±0.50 D ranged from 35.98% (Haigis WK2) to 81.1% (Holladay 1 NLR). Holladay 1 NLR—followed by SRK/T WK2, Holladay 1 MWK, VRF CMAL, PEARL-DGS, and Eom—demonstrated significantly higher accuracy than most other formulas. Haigis WK2 and Hoffer Q WK2 were the least accurate. Certain modified third-generation formulas (Holladay 1 NLR, SRK/T WK2) achieve accuracy comparable to that of new-generation formulas (PEARL-DGS, K6, VRF CMAL) in IOL power calculations for long eyes. However, some third- and fourth-generation formulas—even after AL-based modification (Hoffer Q WK2, Haigis WK2)—continue to yield suboptimal results in this anatomical range.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Stopyra et al. (2026) studied this question.

synapsesocial.com/papers/69af949670916d39fea4b92ahttps://doi.org/10.1016/j.apjo.2026.100301
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Comparative Analysis of Twenty Intraocular Lens Power Calculation Formulas in Medium-Long Eyes2026
  2. 2Accuracy of 20 Intraocular Lens Power Calculation Formulas in Medium-Long Eyes2024 · 23 citations
  3. 3Evaluating predictive accuracy of intraocular lens power calculation formulas in high axial myopia: A comparative analysis2026
  4. 4IOL Power Calculation Formula Accuracy in 1178 Eyes With Short Axial Length:Systematic Reviews and Network Meta-analysis2025
  5. 5Accuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens2024 · 4 citations