Analysis attempts to replicate an innovative copper imaging method in cells, highlighting reproducibility concerns.
The 2012 study by Zhu et al. (DOI: 10.1002/ange.201109089) reporting a hybrid nanosystem composed of carbon and CdSe/ZnS quantum dots functionalized with tris(pyridin‐2‐ylmethyl)ethane‐1,2‐diamine (CdSe@C‐TPEA) as ratiometric fluorescent sensors for intracellular copper imaging remains highly influential, with 499 citations to date (Web of Science, December 4, 2025). As part of the NanoBubbles replication project, we attempted to reproduce key experimental findings following detailed pre‐registered protocols. Despite strict adherence to the reported synthesis procedures, we failed to replicate the central claim of Cu 2+ ‐induced fluorescence quenching. Furthermore, our analysis reveals significant data anomalies in the original publication, including spectral overlaps with identical noise patterns inconsistent with independent measurements. These findings raise critical concerns regarding data integrity and reproducibility and cast significant doubt on the reliability of Zhu et al.’s reported results.
No takes yet. Share an insight, caveat, or question.
Gharib et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: