PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 10, 2026Advanced Functional Materials2 citations

Fluoroelastomer‐Engineered Atmospheric Hygroscopic Hydrogels With Adhesive and Anticorrosive Interfaces for Efficient and Stable Evaporative Cooling

View Full Paper
PSPeiru ShiYLYuzhi LiGLGuoliang Liu

Key Points

  • The study aims to develop a hydrogel that enhances evaporative cooling for electronics while addressing adhesion and corrosion issues.
  • Engineered a fluoroelastomer-based atmospheric hygroscopic hydrogel.
  • Tested adhesion to various substrates through intermolecular interactions.
  • Evaluated cooling performance and temperature reduction capabilities.
  • Achieved an average temperature reduction of 11.3°C.
  • Demonstrated a mean cooling power of 343.8 W m−2 at 60°C over 5 hours.
  • Reduced operating temperature of single-board computers by up to 23.7°C, improving performance by 17.2%.
  • Lowered solar cell temperatures by up to 17.4°C, resulting in a 0.8% efficiency improvement.

Abstract

ABSTRACT The relentless miniaturization and integration of modern electronics intensify overheating issues, driving the need for advanced thermal management solutions. Sorption‐based evaporative cooling, which utilizes atmospheric hygroscopic hydrogels (AHHs) to capture moisture and release it for heat dissipation, presents a promising passive approach. However, conventional AHH‐based evaporative cooling still faces challenges of poor substrate adhesion and halide salt leakage, leading to high interfacial thermal resistance and equipment corrosion. Here, we report a fluoroelastomer‐engineered atmospheric hygroscopic hydrogel (FAHH) with an adhesive and anticorrosive interface for efficient and stable evaporative cooling. The FAHH exhibits robust adhesion to various substrates via multiple intermolecular interactions, ensuring stable thermal contact, while its hydrophobic and electronegative interface effectively suppresses halide leakage to prevent corrosion. Consequently, the FAHH achieves an average temperature reduction of 11.3°C and a mean cooling power of 343.8 W m −2 at 60°C over 5 h. In practical applications, it also reduces the operating temperature of single‐board computer devices by up to 23.7°C (17.2% working performance gain) and that of solar cells under 1 sun illumination by up to 17.4°C (0.8% efficiency improvement). This work provides a promising approach for passive cooling of electronics.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Shi et al. (2026) studied this question.

synapsesocial.com/papers/69af952b70916d39fea4c777https://doi.org/10.1002/adfm.202531131
Ask AI
Helpful
Bookmark
Share
View Full Paper