PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 12, 2026International Journal of Microwave and Wireless Technologies0 citations

A tri-band flexible wearable antenna loaded with an electromagnetic bandgap structure

View Full Paper
YCYong ChenSWShuna WangXHXianfeng He

Key Points

  • The aim is to develop a flexible tri-band monopole antenna with optimized impedance and radiation properties for wearable applications.
  • Integration of a flexible PDMS substrate with a tri-band EBG structure.
  • Introduction of a defected ground structure for better impedance matching.
  • Testing and simulation with a human model to assess SAR levels.
  • Antenna gains of 8.1, 6.64, and 8.21 dBi at 2.45, 3.5, and 5.8 GHz respectively.
  • Good impedance matching across specified frequency bands.
  • SAR values remain below international safety standards.

Abstract

Abstract This paper presents a tri-band flexible wearable monopole antenna integrated with an electromagnetic bandgap (EBG) structure. The antenna uses a flexible PDMS (polydimethylsiloxane) substrate, with resonant frequencies at 2.45, 3.5, and 5.8 GHz, and operates within the frequency bands of 2.42–2.60 GHz, 3.11–3.70 GHz, and 5.32–6.81 GHz. To further optimize the antenna’s impedance matching and radiation characteristics, a defected ground structure is introduced in the design. Additionally, an EBG reflective surface is used to enhance reflection properties, reduce back radiation, improve antenna gain, and decrease the specific absorption rate (SAR). A 4 × 4 tri-band EBG array structure is integrated on the back of the monopole antenna, with each EBG unit consisting of two circular rings and a polygon, achieving zero reflection phase at 2.45, 3.5, and 5.8 GHz. The antenna demonstrates good impedance matching across the designed frequency bands, with a significant gain enhancement of 8.1, 6.64, and 8.21 dBi at the respective frequencies. Simulations with a human model show that the SAR values are below international standards within the operating frequency bands. The antenna also exhibits excellent robustness in its bent state, showing promising potential for applications in medical health monitoring.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Chen et al. (2026) studied this question.

synapsesocial.com/papers/69b2588496eeacc4fcec83efhttps://doi.org/10.1017/s1759078726102967
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Wearable dual‐band dual‐polarized screen‐printed fabric antenna enabled with electromagnetic bandgap structure for ISM and WLAN communications2024
  2. 2Curvature-Adaptive Compact Triple-Band Metamaterial Uniplanar Compact Electromagnetic Bandgap-Based Printed Antenna for Wearable Wireless and Medical Body Area Network Applications2024 · 12 citations
  3. 3Miniaturized textile flexible antenna with electromagnetic band gap for wearable application2024
  4. 4Wideband U‐Shaped Wearable Antenna With Defected Ground Structure for Biomedical Wearables2025 · 3 citations
  5. 5Design of compact multi stub resonator based flexible monopole antenna for 5G wearable applications in N77 and N78 bands2026