Frequent large-scale construction projects have rendered subway box structures vulnerable to displacements. This study examined the adequacy of foundation reinforcement for a subway box structure exhibiting displacement behavior. A displacement function was derived from the optical leveling data, and a three-dimensional numerical analysis was performed by applying the computed subgrade elastic modulus as a boundary condition. The analysis produced estimates of uplift and subsidence at the nodes along both the transverse and longitudinal directions of the structure. To determine the required amount of reinforcement (grouting volume), the nodal reinforcement depth obtained from the analysis was applied to a grid-based volumetric calculation method. The nodal intervals were subdivided to the maximum feasible extent, and rectangular grids with sufficient resolution were established to ensure accurate reinforcement-volume calculation. The reinforcement volumes estimated through the numerical analysis were compared with actual field values to assess the adequacy of the foundation reinforcement. Some differences were observed, which were attributed to field constraints that prevented reinforcements at certain required locations. Based on these findings, additional reinforcements can be applied at the analytically identified locations to ensure the structural safety of the subway box structure.
Choi et al. (Wed,) studied this question.