PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 19, 2026Industrial Construction0 citations

Mechanical Property of Precast Slab-Assembled Utility Tunnel with UHPC Connections

SCSile CHENSCShengyang CHENJJJiafei JIANG

Key Points

  • This research aims to evaluate the mechanical properties of precast slab-assembled utility tunnels with UHPC connections.
  • Developed a finite element model of the utility tunnel using ABAQUS software.
  • Conducted joint tests to validate the model's accuracy.
  • Performed parametric analysis focusing on axial compression ratios and UHPC segment locations.
  • Precast model's bearing capacity was 3% lower than the cast-in-place model.
  • Increased axial compression ratios improved bearing capacities by up to 18.3%.
  • Ductility coefficients decreased significantly with higher axial compression ratios.

Abstract

A precast slab-assembled concrete utility tunnel connected by Ultra-High Performance Concrete (UHPC) consists of a base slab, sidewalls, and a roof slab, and the rebars protruding from the base slab are lap-spliced with the longitudinal reinforcement of the sidewall by UHPC. To study the mechanical properties of the precast slab-assembled concrete utility tunnel with UHPC connections, an overall model of the utility tunnel was established based on the commercial finite element software ABAQUS. A joint test of the utility tunnel was conducted to validate the model’s rationality. The failure modes, bearing capacity, and ductility of the specimens were in good agreement with the finite element calculation results. On this basis, a parametric finite element analysis was conducted, focusing on key parameters such as the axial compression ratio (0.05, 0.1, and 0.15) and the vertical location of the UHPC cast-in-place segment (at the base slab top surface, and 350 mm above it, and 500 mm above it). The finite element analysis results showed that both precast and cast-in-place models failed due to sidewall flexure, with the bearing capacity of the precast model being 3% lower than that of the cast-in-place model. Compared to the utility tunnel with an axial compression ratio of 0, the bearing capacities of the models with axial compression ratios of 0.05, 0.1, and 0.15 increased by 11.6%, 15.4%, and 18.3%, respectively, while their ductility coefficients decreased by 2.4%, 5.4%, and 8.6%, respectively. The location of the UHPC cast-in-place segment had little effect on the overall bearing capacity and ductility of the utility tunnel structure. In general, the precast slab-assembled concrete utility tunnel with UHPC connections has good mechanical properties and shows broad prospects for engineering applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

CHEN et al. (2026) studied this question.

synapsesocial.com/papers/69bb92d1496e729e62980698https://doi.org/10.3724/j.gyjzg25121707
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Seismic performance of a novel interior precast concrete beam-column joint using ultra-high performance concrete2020 · 107 citations
  2. 2建筑工程施工中的混凝土浇筑施工技术分析2023 · 3 citations
  3. 3Flexural behavior of UHPC joints for precast UHPC deck slabs2021 · 71 citations
  4. 4Composition of reactive powder concretes1995 · 2,327 citations