PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 19, 2026Nature Communications4 citationsOpen Access

Unlocking large-area free-standing MOF-glasses for molecular sieving gas separation membranes

OSOksana SmirnovaADAlexis DuvalAKAyisha Komal

Key Points

  • This research aims to develop large, crack-free MOF-glass membranes for effective gas separations.
  • Selection and optimization of materials to improve thermal and mechanical behavior of MOF-glass.
  • Fabrication of self-supported ZIF-62 glass membranes through controlled melting processes.
  • Investigation of microstructure using microscopy and SEM-EDX analysis.
  • Conducting gas permeation experiments to evaluate membrane performance.
  • Successfully manufactured crack-free, self-supported ZIF-62 glass membranes.
  • Confirmed homogeneous boundary-free MOF-glass structure through microscopy.
  • Exhibited sharp methane sieving cut-off with exceedingly low permeability, undetectable by gas chromatography.

Abstract

Abstract Membranes from MOF glasses hold significant promise for gas separations due to the absence of grain boundary diffusion, liquid processibility, and tunability. The inherent high viscosity of MOF melts renders them prone to cracking and further handling, and their propensity to densify at high temperatures and long time in molten state severely limits their upscaling potential. A solution to overcome these limitations is demonstrated by selecting suitable materials that fit the thermal and mechanical behaviour to MOF-glass, enabling processing and making of large, crack-free MOF-glass sheets. This is demonstrated on the example of the well-known MOF-glass former ZIF-62. By optimizing each step of the process – from melting to performance testing – we successfully fabricate a crack-free, self-supported ZIF-62 glass membrane. The microstructure is investigated using microscopy as well as SEM-EDX analysis, confirming homogeneous boundary-free MOF-glass, while gas permeation experiments prove the applicability of MOF-glass as gas separation membrane. The membrane exhibits exceptionally sharp methane molecular sieving cut-off with such low permeability that gas chromatography is unable to detect CH 4 . We conclude this work by giving a brief outlook of the remaining challenges and perspectives for MOF glasses, envisioning transferability of our approach to other glass-forming systems and their scaling perspectives.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Smirnova et al. (2026) studied this question.

synapsesocial.com/papers/69bb9345496e729e629814cfhttps://doi.org/10.1038/s41467-026-70571-4
Ask AI
Helpful
Bookmark
Share
View Full Paper