Analysis reveals significant performance decline in photovoltaic modules, indicating the need for better materials.
This study presents a 15-yr real-field performance and degradation analysis of photovoltaic modules in a Mediterranean climate. Three technologies—polycrystalline silicon (p-Si), monocrystalline silicon, and amorphous silicon—were monitored, with a detailed forensic focus on the most severely degraded p-Si systems. The p-Si modules exhibited an average degradation rate of 2.56%/year, significantly exceeding the manufacturer's warranty. Laboratory flash tests confirmed power losses of −33% to −70% over fifteen years. A multi-method diagnostic approach, integrating electroluminescence, ultraviolet fluorescence, lock-in thermography, and material forensics, identified two primary synergistic degradation pathways. The first involves optical losses from encapsulant yellowing, reducing current uniformly. The second, and more critical, is a severe increase in series resistance caused by interconnect corrosion and delamination, which drastically reduces the fill factor. Microcracks, while widespread, were a secondary factor. The study unequivocally links the degradation to moisture, oxygen, and light exposure, as evidenced by localized protection under a metal-backed nameplate. These findings underscore the critical discrepancy between accelerated testing and field aging, highlighting the necessity of long-term monitoring for accurate lifetime predictions and the development of more durable module materials and designs.
No takes yet. Share an insight, caveat, or question.
Tsanakas et al. (2026) studied this question.