This research develops a novel method to evaluate gas production rates in underground gas storage, indicating its effective application potential.
To achieve high-precision and real-time quantitative evaluation of gas production in underground gas storage (UGS), this study focused on 11 typical injection-production wells in the Sudong UGS group. To address the common challenges posed by deviated well structures and complex wellbore temperature field distributions, a gas flow-rate calculation method based on Distributed Temperature-Sensing (DTS) data was developed. By standardizing the processing of multi-well temperature data, deviated wellbore trajectories were straightened to convert measured depth (MD) to true vertical depth (TVD). By incorporating a geothermal correction mechanism, temperature anomalies closely related to fluid flow were extracted, and a spatially unified temperature field model was constructed. On this basis, a “Dual-Point Temperature Difference Method” is proposed as a novel approach for single-well production evaluation. Based on thermodynamic phenomena such as the Joule–Thomson effect and expansion cooling, two critical sensing points, upstream and downstream of the production layer, were selected, with their temperature anomaly difference (∆T) serving as a sensitive indicator of flow rate variations. Combined with downhole pressure parameters and synchronized wellhead metering data, a nonlinear quantitative relationship model between ∆T and gas production rate Q was established, enabling accurate conversion of wellbore thermal response to macroscopic flow parameters. The results indicated that the gas production rates calculated by this method align well with traditional wellhead metering data, with errors maintained within engineering tolerances. Notably, the method demonstrates higher reliability and corrective capabilities in wells with drifting or faulty meters. This achievement breaks the reliance of traditional methods on specific layers or mechanical meters. It enables the effective application of multi-well, full-section, and non-contact temperature data in gas volume assessment. This research provides new technical support for dynamic monitoring, efficient operation, and remaining gas evaluation of UGS, offering significant prospects for engineering applications.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: