PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 25, 2026Angewandte Chemie International Edition4 citations

Shallow‐Trap Perovskite Scintillators for High‐Resolution, Ghosting‐Free X‐Ray Imaging

View Full Paper
WLWei LiYYYao YaoLZLibin Zheng

Key Points

  • The goal is to develop scintillators that overcome limitations of traditional X-ray imaging, focusing on improving radioluminescence and reducing ghosting.
  • Developed Cs2ZrCl6:Te4+ perovskite scintillators with shallow electron-hole traps.
  • Conducted spectroscopic and theoretical studies to analyze defect dynamics.
  • Embedded scintillators in a flexible PDMS matrix to create imaging films.
  • Achieved a spatial resolution of 18.5 lp mm-1 in time-lapse X-ray imaging.
  • Demonstrated long-lasting radioluminescence at room temperature with recyclability.
  • Showed optimized defect landscape due to Te4+ doping, improving charge trapping and release.

Abstract

Solution-processed scintillators exhibiting long-lasting radioluminescence upon X-ray irradiation hold great promise for flexible and high-resolution X-ray imaging. However, their practical implementation is typically impeded by deep electronic traps that require thermally stimulated readout at high temperature to release stored charges, leading to image ghosting and limited recyclability. Here, we report Cs2ZrCl6:Te4+ perovskite scintillators featuring X-ray-induced Frenkel defect-associated shallow traps that enable long-lasting radioluminescence at room temperature. Spectroscopic and theoretical studies reveal that X-ray irradiation generates shallow electron-hole traps, which facilitate efficient charge capture and thermal release, producing persistent luminescence under ambient conditions. Te4+ doping optimizes the defect landscape, stabilizing shallow traps and promoting favorable charge trapping-detrapping dynamics. By embedding these microcrystals into a flexible PDMS matrix, we fabricate a scintillating film capable of high-resolution, ghosting-free, time-lapse X-ray imaging with a spatial resolution of 18.5 lp mm-1 and recyclable imaging performance. This study highlights the potential of shallow-trap perovskite scintillators for next-generation flexible X-ray imaging technologies.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Li et al. (2026) studied this question.

synapsesocial.com/papers/69c37b33b34aaaeb1a67d6f2https://doi.org/10.1002/anie.4716874
Ask AI
Helpful
Bookmark
Share
View Full Paper