Individualized electrode subset improves the calibration accuracy of an EEG P300-design brain-computer interface for people with severe cerebral palsy

STSi Long Jenny TouSWSeth WarschauskyPKPetra Karlsson

Key Points

  • To investigate the impact of personalized electrode locations on EEG BCI calibration accuracy for individuals with cerebral palsy.
  • Conducted a post-hoc offline analysis on 51 participants with varying severity of cerebral palsy.
  • Utilized a forward selection algorithm to determine optimal electrode locations for each individual.
  • Compared accuracy of individualized electrode subsets against a standard default subset.
  • Individualized subsets improved calibration accuracy by an average of 28.6% for the severe cerebral palsy group.
  • No significant accuracy improvement was found for mild cerebral palsy or typically developing controls at the group level.
  • In testing, calibration gains did not enhance overall accuracy, particularly showing a −9.6% drop among controls.

Abstract

Introduction This study examined the effect of individualized electroencephalogram (EEG) electrode location selection for non-invasive P300-design brain-computer interfaces (BCIs) in people with varying severity of cerebral palsy (CP) in a post-hoc offline analysis. Methods A forward selection algorithm was used to select the best performing eight electrodes (of an available 32) to construct an individualized electrode subset for each participant. Custom electrode subset size was chosen to be 8 because BCI accuracy of the individualized subset was compared to accuracy of a widely used default subset. Results Across 51 participants, individualized subsets improved calibration accuracy only for the severe CP cohort (mean +28.6% absolute; 95% CI 13.4%, 46.1%; p 0.0001). No group-level benefit was detected for mild CP or typically developing controls, although several individuals in these groups improved (2/17 mild CP; 1/10 controls). In the subset with held-out testing data (mild CP and controls), calibration gains did not translate to higher testing accuracy; among controls, the subset effect was reduced on testing (−9.6%, 95% CI −13.3%, −5.8%, p 0.0001), with no evidence of change for mild CP. Participants with severe CP typically required larger subsets to approach asymptotic accuracy, whereas ≤ 8 electrodes were sufficient for most others. Discussion The findings suggested that electrode selection can accommodate atypical neuroanatomy in people with severe CP, while the default electrode locations are sufficient for people with milder impairments from CP and typically developing individuals.