Investigating tilt-to-length coupling stability in LISA Pathfinder, indicating temperature-related distortions impact performance.
The tilt-to-length coupling during the LISA Pathfinder mission has been numerically and analytically modeled for particular time spans. In this work, we investigate the long-term stability of the coupling coefficients of this noise. We show that they drifted slowly (by 1 μm/rad and 6×10-6 in 100 days) and were strongly correlated to temperature changes within the satellite (8 μm/rad/K and 30×10-6/K). Based on analytical tilt-to-length coupling models, we attribute the temperature-driven coupling changes to rotations of the test masses and small distortions in the optical setup. Particularly, our findings lead to the conclusion that LISA Pathfinder's optical baseplate was bent during the cooldown experiment, which started in late 2016 and lasted several months.
No takes yet. Share an insight, caveat, or question.
Armano et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: