Patient-specific fluid-structure interaction computational models of the aortic valve accurately replicated in vivo 4D flow MRI dynamics in five patients with aortic stenosis.
Do patient-specific fluid-structure interaction models accurately replicate in vivo flow dynamics compared to 4D flow MRI in patients with aortic stenosis?
Patient-specific fluid-structure interaction models validated against 4D flow MRI can accurately replicate aortic flow dynamics and compute additional metrics like blood residence time to enhance aortic stenosis assessment.
Abstract Systematic in vivo validations of computational models of the aortic valve (AV) remain scarce, despite successful validation against in vitro data. Utilizing a combination of computed tomography and 4D flow magnetic resonance imaging data, we developed patient‐specific fluid–structure interaction models of the AV immersed in the aorta for five patients in the pre‐transcatheter AV replacement configuration. Our computational models are subjected to rigorous validation against 4D flow measurements. Our results demonstrate the models’ capacity to accurately replicate flow dynamics. In addition, we illustrate how computational models can serve as valuable cross‐checks to reduce noise and erratic behaviour of in vivo data. Crucially, our validated models enable the measurement of additional critical quantities essential for a comprehensive understanding of aortic stenosis (AS) and its treatments: we compute the blood residence time, enhancing precision and personalization in assessing the probability of thrombus formation within the aorta. This study represents a significant step towards integrating in silico technologies into real clinical contexts, providing a robust framework for improving AS diagnosis and the design of next‐generation AV bioprostheses. image Key points Patient‐specific fluid–structure interaction computational models of the aortic valve are developed for five patients in pre‐transcatheter aortic valve replacement configuration. A synergistic approach involving in silico models and in vivo data is utilized, including computed tomography and 4D flow magnetic resonance imaging. A patient‐specific calibration strategy is introduced to identify the aortic valve Young's modulus, leveraging in vivo flow‐derived metrics in combination with patient‐specific valve and aortic geometries. The computational models are validated against in vivo 4D flow measurements, demonstrating their ability to replicate flow dynamics accurately. The potential of computational models to cross‐check and reduce noise in in vivo data is highlighted, providing additional critical physiological quantities for comprehensive aortic stenosis assessment, such as blood residence time, important for thrombus formation evaluation.
Zingaro et al. (Sat,) conducted a other in Aortic stenosis (n=5). Patient-specific fluid-structure interaction computational models vs. In vivo 4D flow MRI measurements was evaluated on Replication of flow dynamics. Patient-specific fluid-structure interaction computational models of the aortic valve accurately replicated in vivo 4D flow MRI dynamics in five patients with aortic stenosis.