Evaluation of thermal and RF behavior in microwave satellite antennas, indicating readiness for missions.
AbstractThe microwave remote sensing satellite’s tile antennas are crucial for operational success. This study evaluates the thermal and RF behaviour of 1 m × 1 m honeycomb quartz tiles bonded with cyanate ester adhesive, tested in a gaseous Nitrogen–based thermal vacuum system at SAC-ISRO. Unlike conventional setups, the system achieved a temperature gradient of = 2 K across the antenna surface, surpassing the standard requirement of = 10 K. Strategic placement optimized radiation heat transfer, while precise shroud control ensured uniform thermal exposure during cycling between 253 K and 358 K. Radio Frequency (RF) measurements confirmed stable dual-polarization performance, with return losses consistently below 10 dB. Measurement uncertainties (±0.1 K for temperature sensors, ±0.05 dB for RF data) validated the robustness of results. The findings establish an integrated thermal–RF validation methodology, confirming antenna readiness for operational missions and contributing to reliable, cost-effective satellite systems.
No takes yet. Share an insight, caveat, or question.
Patra et al. (2024) studied this question.