To investigate the characteristics of pressure pulsation induced by vortex ropes in the draft tube of a centrifugal pump under runaway conditions, a closed double-layer hydraulic test bench was established in this study. Runaway characteristic experiments were conducted, and pressure pulsation signals were acquired at heads of 7.6 m, 9.6 m, and 11.9 m. The measured pressure data were analyzed in the time–frequency domain using Fast Fourier Transform (FFT) and Wavelet Transform (WT). The results show that both the runaway rotational speed and the reverse flow rate increase with increasing head. Under all three heads, the dominant frequency upstream of the elbow section of the draft tube is 0.53 times the rotational frequency, confirming that the vortex rope in the draft tube serves as the primary excitation source of the flow field. As the vortex rope is conveyed by the main flow through the elbow, it undergoes impingement and fragmentation, causing the dominant frequency downstream of the elbow to decrease to 0.1 times the rotational frequency. The dominant frequency induced by the vortex rope remains continuous over time, whereas the frequency arising from the coupling between the vortex rope and rotor–stator interaction exhibits pronounced time-varying oscillations. These oscillations intensify with increasing head, and their frequency oscillation range broadens from 4 to 6 times the rotational frequency at low head to 2–8 times at high head. These findings provide a theoretical foundation for the preventive and protective design of centrifugal pumps under runaway conditions.
Dai et al. (Sun,) studied this question.