T1ρ tendon imaging requires angle correction; leaves open standardized protocols for clinical diagnostics.
An ultrashort TE T(1)ρ sequence was used to measure T(1) ρ of the goat posterior cruciate ligament (n = 1) and human Achilles tendon specimens (n = 6) at a series of angles relative to the B(0) field and spin-lock field strengths to investigate the contribution of dipole-dipole interaction to T(1)ρ relaxation. Preliminary results showed a significant magic angle effect. T(1)ρ of the posterior cruciate ligament increased from 6.9 ± 1.3 ms at 0° to 36 ± 5 ms at 55° and then gradually reduced to 12 ± 3 ms at 90°. Mean T(1)ρ of the Achilles tendon increased from 5.5 ± 2.2 ms at 0° to 40 ± 5 ms at 55°. T(1)ρ dispersion study showed a significant T(1)ρ increase from 2.3 ± 0.9 ms to 11 ± 3 ms at 0° as the spin-lock field strength increased from 150 Hz to 1 kHz, and from 30 ± 3 ms to 42 ± 4 ms at 55° as the spin-lock field strength increased from 100 to 500 Hz. These results suggest that dipolar interaction is the dominant T(1)ρ relaxation mechanism in tendons and ligaments.