PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 8, 2026Chemical & Biomedical Imaging0 citationsOpen Access

Tetrahedral DNA Framework–Bridged Aptasensing Method for Ultrasensitive Determination of Cardiac Troponin I

View Full Paper
JCJiaqi CaiWZWenshuai ZhouLGLiang Gao

Key Points

  • The aim is to develop an ultrasensitive method for detecting cardiac troponin I, a biomarker for acute myocardial infarction.
  • Developed a tetrahedral DNA framework-bridged aptasensing method.
  • Utilized electrogenerated chemiluminescence and fluorescence imaging for detection.
  • Designed a TDF-aptamer as a capture probe on a gold electrode.
  • Created a signal probe using magnetic Fe3O4 carriers.
  • Achieved a linear detection range of 5 to 80 pg/mL using ECL intensity.
  • Demonstrated sensitivity from 0.5 to 500 pg/mL with combined ECL and fluorescence imaging.
  • Showed enhanced specificity and recognition for cardiac troponin I.

Abstract

The development of a sensitive and accurate method for the determination of cardiac troponin I (cTnI), as an ideal biomarker of acute myocardial infarction (AMI), is critical for the early diagnosis of AMI. In this work, a tetrahedral DNA framework (TDF)-bridged aptasensing method was proposed for the ultrasensitive determination of cTnI via electrogenerated chemiluminescence (ECL) and fluorescence imaging methods, in which a specific anti-cTnI aptamer-tagged tetrahedral DNA framework (TDF-aptamer) was designed as a capture probe by incorporating a specific aptamer against cTnI within the three-dimensional TDF. The TDF-aptamer was modified onto a gold electrode surface through the Au–S bond, providing a specifically captured platform for cTnI with a 3D binding space at the nanoscale. One microsized signal probe (Ab2-biotin•SA@MB-Ru1) was synthesized by using magnetic Fe3O4 as carriers to load a large amount of ruthenium complex and a specific cTnI antibody. After the sandwich assay among the modified TDF-aptamer, cTnI, and the signal probe, both ECL and fluorescence signals were recorded for the cTnI assay with desirable selectivity and high sensitivity (linear range of 5 to 80 pg/mL using ECL intensity detection and 0.5 to 500 pg/mL using ECL and fluorescence imaging methods). This work demonstrated that the combination of the specific TDF-aptamer and microsized Ab2-biotin•SA@MB-Ru1 within the imaging method can enhance the specific recognition and detection sensitivity for cTnI, which is promising for AMI diagnosis.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Cai et al. (2026) studied this question.

synapsesocial.com/papers/69d5f05d74eaea4b11a79b9bhttps://doi.org/10.1021/cbmi.5c00292
Ask AI
Helpful
Bookmark
Share
View Full Paper