High-performance X-ray scintillators with low detection limits and high light yield are of great importance and are a challenge for low-dose X-ray imaging in medical diagnosis and industrial detection. In this work, the synthesis of a new 2D perovskite, Cs₂ CdBr₂ Cl₂ , via hydrothermal reaction is reported. By doping Mn²⁺ into the perovskite, a yellow emission located at 593 nm is obtained, and the photoluminescence quantum yield (PLQY) of Cs₂ CdBr₂ Cl₂ :5%Mn²⁺ perovskite reaches the highest value of 98.52%. The near-unity PLQY and negligible self-absorption of Cs₂ CdBr₂ Cl₂ :5%Mn²⁺ enable excellent X-ray scintillation performance with a high light yield of 64 950 photons MeV⁻¹ and low detection limit of 17.82 nGyair s⁻¹ . Moreover, combining Cs₂ CdBr₂ Cl₂ :5%Mn²⁺ with poly(dimethylsiloxane) to fabricate a flexible scintillator screen achieves low-dose X-ray imaging with a high resolution of 12.3 line pairs (lp) mm⁻¹ . The results suggest that Cs₂ CdBr₂ Cl₂ :5%Mn²⁺ is a promising candidate for low-dose and high-resolution X-ray imaging. The study presents a new approach to designing high-performance scintillators through metal-ion doping.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: