Answers are grounded in this paper and cite their sources.
Potentiodynamic analysis investigates corrosion behaviour in rebars, highlighting mill scale's dual role in protection and vulnerability.
Potentiodynamic polarisation, electrochemical impedance spectroscopy, real-time video recording and microscopy were used to investigate the passivation and corrosion behaviour of HPB300 reinforcing steel in simulated concrete pore solution (SCPS). Three surface conditions were examined: polished rebar without mill scale (PR), as-received rebar with intact mill scale (AR) and rebar with defective mill scale (DR). The results show that PR more readily develops a dense, uniform passive film in SCPS, whereas the passive film formed on mill-scale-covered rebars is of lower quality. Despite its inferior passive film quality, intact mill scale provides additional physical shielding, delaying pitting initiation in low-chloride environments; below 0.6 mol/L Cl − , AR exhibited a pitting potential of approximately 0.8 V. However, once a local breakdown occurs, pitting preferentially initiates at weak regions of the mill scale. The resulting electrochemical heterogeneity and geometric discontinuities on the mill-scale surface further intensify localised attack, leading to larger pitting cavities and faster corrosion propagation than observed on PR. These findings elucidate the dual role of mill-scale integrity in chloride-bearing alkaline environments and provide mechanistic evidence to improve the durability of reinforcing steel.
No takes yet. Share an insight, caveat, or question.
Zeng et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: