January 8, 2023Journal of Chromatography A46 citationsOpen Access

Comprehensive evaluation of zwitterionic hydrophilic liquid chromatography stationary phases for oligonucleotide characterization

HLHonorine LardeuxDGDavy GuillarmeVDValentina D’Atri

Key Points

Key points are not available for this paper at this time.

Abstract

Hydrophilic interaction chromatography (HILIC) has been proposed as a valuable alternative to ion-pairing reversed-phase chromatography (IP-RPLC) for oligonucleotide (ON) analysis. In this context, the potential of seven zwitterionic HILIC columns has been evaluated against amide- and poly-hydroxy fructan-functionalized HILIC columns and a C18 column operated under IP-RPLC mode. Based on the retention characteristics of key small molecule pairs, each zwitterionic HILIC column showed a unique radar-shaped profile, suggesting different selectivities for distinct structural differences. Unmodified DNA and RNA samples were then evaluated, and the columns classified based on their retentivity. Two zwitterionic columns were particularly promising in terms of overall resolution, especially for the largest ONs (> 40-mer). Finally, separations between a chemically modified drug-like ON and its closely related impurities were performed. Although the ZIC-cHILIC column showed similar selectivity values as compared to the reference IP-RPLC technique, all columns demonstrated a general decrease in selectivity due to the minor structural differences present in the highly complex samples. This work highlights the utility of zwitterionic HILIC mode for ON analysis and it reveals the importance of understanding columns characteristics - in terms of retention and selectivity - when selecting a stationary phase for specific ON applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lardeux et al. (2023) studied this question.

synapsesocial.com/papers/69d8aa0c52654bb436d19abdhttps://doi.org/10.1016/j.chroma.2023.463785
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1The combined effect of silanols and the reversed-phase ligand on the retention of positively charged analytes2004 · 98 citations
  2. 2Impact of stationary-phase pore size on chromatographic performance using oligonucleotide separation as a model2020 · 33 citations
  3. 3Impurities in Oligonucleotide Drug Substances and Drug Products2017 · 134 citations
  4. 4Ion-pair reversed-phase high-performance liquid chromatography analysis of oligonucleotides:2002 · 215 citations
  5. 5Kinetics of phosphorothioate oligonucleotide metabolism in biological fluids1997 · 58 citations