August 4, 2020Structure and Infrastructure Engineering177 citations

Experimental study of predamaged columns strengthened by HPFL and BSP under combined load cases

View Full Paper
HHHua HuangMHMin HuangWZWei Zhang

Key Points

Key points are not available for this paper at this time.

Abstract

After the ground motion, a large number of columns remain intact and can be retrofitted and reused. In this paper, to explore the effects of the loading scenario, predamage level and strengthening measures on the seismic performance of reinforced concrete (RC) columns, seven predamaged specimens strengthened with high-performance ferrocement laminate (HPFL) and bond steel plate (BSP) were tested. The results show that the bearing capacity, ductility, single-cycle energy dissipation and stiffness of all the predamaged specimens can be effectively restored and improved by this strengthening method for different loading cases. This strengthening method also significantly improves the shear capacity and changes the failure modes of the predamaged strengthened specimens from those of the corresponding predamaged unstrengthened specimens. The vertical eccentricity only slightly affects the seismic behavior of the specimens, while the horizontal eccentricity significantly increases the length of the failure region and reduces the seismic behavior of the specimens, considering the bearing capacity, energy dissipation capacity, and stiffness. The effects of different predamage levels are unique.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Huang et al. (2020) studied this question.

synapsesocial.com/papers/69d8f4902c87b79b92d185d4https://doi.org/10.1080/15732479.2020.1801768
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Experimental Investigation and Design of Concrete-Filled Steel Tubular CHS Connections2014 · 51 citations
  2. 2Torsional Repair of Severely Damaged Column Using Carbon Fiber-Reinforced Polymer2014 · 37 citations
  3. 3Seismic-Response Analysis of RC C-Shaped Core Walls Subjected to Combined Flexure, Shear, and Torsion2018 · 29 citations
  4. 4Hysteretic shear–flexure interaction model of reinforced concrete columns for seismic response assessment of bridges2010 · 75 citations
  5. 5Parametric Analysis of Seismic Performance of RC Columns Strengthened with Steel Wire Mesh2014 · 1 citations