The current work is an experimental investigation of the dependence of film cooling effectiveness on the injection Mach number, velocity, and mass flux. The freestream Mach number is 2.4, and the injection Mach numbers range from 1.2 to 2.2 for both air and helium injection. The adiabatic wall temperature is measured directly. The injection velocity and mass flux are varied by changing the total temperature and Mach number while maintaining matched pressure conditions between the injected flow and that of the freestream. The total temperature of the freestream is 295 K, and for the injection it ranges from 215-390 K. The results indicate an increase in film cooling effectiveness as the injection rate is increased. With the exception of heated helium runs, larger injection Mach numbers slightly increase the effective cooling length per mass injection rate. The results for helium injection indicate an increase in effectiveness as compared to that for air injection. Heated injection, with the injectant to freestream velocity ratios greater than 1, exhibit a rise in wall temperature downstream of the slot resulting in effectiveness values greater than 1. The experimental results are also compared with earlier studies in the literature.