This is the authors' abstract. We don't add key points for this paper.
We propose, optimize, fabricate and test beam-steering elements based on double-sided liquid-crystal (LC) metasurfaces allowing for diffractive and spectral multiplexing, and thus covering three different beam deflection directions each. While straightforward parallel design requires one diffractive beam-steering element per a direction determined by Bragg’s law, double-sided LC-metasurfaces are remarkably flexible and allow optimization for three operation modes at different applied voltages: zero-voltage mode with dominant +1 order red light and +2 order blue light diffraction; intermediate mode at 1.4–1.6 V voltage with dominant +1 order blue light diffraction; and transparent mode at 5 V voltage. We comprehensively study three such elements with 6, 8 and 10 micrometer periods and verify their capability of deflecting blue and red light beams with 40–70% efficiencies in nine target directions with 10 ms characteristic switching times.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Gorkunov et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: