This work describes the development and validation of a patient-specific Monte Carlo internal dosimetry platform called RAPID (Radiopharmaceutical Assessment Platform for Internal Dosimetry). RAPID utilizes serial PET/CT or SPECT/CT images to calculate voxelized three-dimensional (3D) internal dose distributions with the Monte Carlo code Geant4. RAPID's dosimetry calculations were benchmarked against previously published S-values and specific absorbed fractions (SAFs) calculated for monoenergetic photon and electron sources within the Zubal phantom and for S-values calculated for a variety of radionuclides within spherical tumor phantoms with sizes ranging from 1 to 1000 g. The majority of the S-values and SAFs calculated in the Zubal Phantom were within 5% of the previously published values with the exception of a few 10 keV photon SAFs that agreed within 10%, and one value within 16%. The S-values calculated in the spherical tumor phantoms agreed within 2% for ¹⁷⁷Lu, ¹³¹I, ¹²⁵I, ¹⁸F, and ⁶⁴Cu, within 3.5% for ²¹¹At and ²¹³Bi, within 6.5% for ¹⁵³Sm, ¹¹¹In, ⁸⁹Zr, and ²²³Ra, and within 9% for ⁹⁰Y, ⁶⁸Ga, and ¹²⁴I. In conclusion, RAPID is capable of calculating accurate internal dosimetry at the voxel-level for a wide variety of radionuclides and could be a useful tool for calculating patient-specific 3D dose distributions.
No takes yet. Share an insight, caveat, or question.
Besemer et al. (2018) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: