Answers are grounded in this paper and cite their sources.
In this article, the fast-scale instability in the three-level T-type single-phase inverter feeding diode-bridge rectifier with inductive load (3TSI-DR) is studied. Simulations suggest that such fast-scale instability on switching period scale can increase the harmonic content in the 3TSI-DR, which seriously affects its stable operation. To reveal the mechanism of this fast-scale instability, the state equation of the 3TSI-DR is derived, and state variables are solved based on quasi-static approximation principle. From state equation, the 3TSI-DR is periodic time-varying and piecewise smooth, belonging to Filippov system. Accordingly, the discrete-time mapping model of the 3TSI-DR is established, Filippov method is used for obtaining monodromy matrix, and Floquet theory is applied to explore instability mechanism. Theoretical results indicate that the fast-scale instability of the 3TSI-DR is caused by period-doubling bifurcation. Moreover, the Floquet multiplier sensitivities of different circuit parameters are calculated to identify key parameters; via comparing theoretical analyses with simulations, the unstable angle ranges of the fast-scale instability are given, and the stability boundaries in various parameter spaces are discussed. All these can provide design-oriented information for optimizing the 3TSI-DR to avoid instability due to period-doubling bifurcation. Finally, experimental results agreeing with simulations are presented to verify the correctness of theoretical analyses.
No takes yet. Share an insight, caveat, or question.
Cao et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: