This approach enhances voltage stability in DFIG systems by integrating advanced control strategies during grid disturbances, suggesting improved performance.
The increasing penetration of Doubly Fed Induction Generator (DFIG)-based wind energy systems raises major concerns regarding voltage stability and Fault Ride-Through (FRT) capability under grid disturbances and wind speed variations. This paper proposes a coordinated control framework for a grid-connected DFIG system, where a Static Synchronous Compensator (STATCOM) based on discrete-time deadbeat current control is integrated with a Supercapacitor Energy Storage System (SCES) connected to the DC link through a bidirectional DC-DC converter governed by cascaded Active Disturbance Rejection Control (ADRC). The deadbeat-controlled STATCOM provides fast reactive current injection for voltage support during sag and swell events, while the cascaded ADRC enhances DC-link voltage regulation and suppresses rotor-speed oscillations. Comprehensive MATLAB/Simulink simulations are carried out under variable wind speed and severe grid disturbances up to 80% voltage sag and 50% voltage swell. For voltage regulation, the proposed method is compared with SVC and PI-based STATCOM. In addition, SCES control performance is evaluated by comparing PI, single ADRC, and cascaded ADRC in terms of DC-link voltage overshoot, undershoot, and ripple. The results show clear improvements in voltage response and transient performance. Under a 20% voltage sag, the proposed deadbeat-controlled STATCOM significantly improves the dynamic response, where the undershoot is reduced from 0.125 p.u. (with SVC) to 0.04 p.u., and the settling time is shortened from 0.04 s to 0.025 s. Under a severe 80% sag, the overshoot is limited to 0.02 p.u., compared with 0.13 p.u. for the SVC and 0.15 p.u. for the PI-based STATCOM. Similarly, under a 50% voltage swell, the overshoot is reduced to 0.20 p.u., compared with 0.46 p.u. for the SVC and 0.27 p.u. for the PI-based STATCOM. Regarding the DC-link performance under 80% sag, the proposed cascaded ADRC-based SCES limits the overshoot and undershoot to 6 V and 2 V, respectively, compared with 39 V and 32 V for the PI-based SCES. These results confirm the superior damping, disturbance rejection, and FRT enhancement achieved by the proposed strategy.
No takes yet. Share an insight, caveat, or question.
Nori et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: