PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
November 1, 2009Water Science & Technology153 citations

Evaluation of the apparent losses caused by water meter under-registration in intermittent water supply

View Full Paper
ACAntonio CriminisiCFChiara Maria FontanazzaGFGabriele Freni

Key Points

  • To evaluate how water meter aging and private storage tanks contribute to meter under-registration and apparent water losses in intermittent water supply networks.
  • Evaluated the impact of meter aging by laboratory testing 180 revenue meters ranging from 0 to 45 years in age from Palermo, Italy.
  • Quantified the effects of private storage tanks fed by float valves using field monitoring of real users combined with mathematical modeling.
  • Apparent losses resulting from the meter starting flow threshold increased rapidly with meter age.
  • Private water storage tanks amplified meter under-registration, generating additional apparent losses between 15% and 40% across the analyzed users.

Abstract

Apparent losses are usually caused by water theft, billing errors, or revenue meter under-registration. While the first two causes are directly related to water utility management and may be reduced by improving company procedures, water meter inaccuracies are considered to be the most significant and hardest to quantify. Water meter errors are amplified in networks subjected to water scarcity, where users adopt private storage tanks to cope with the intermittent water supply. The aim of this paper is to analyse the role of two variables influencing the apparent losses: water meter age and the private storage tank effect on meter performance. The study was carried out in Palermo (Italy). The impact of water meter ageing was evaluated in laboratory by testing 180 revenue meters, ranging from 0 to 45 years in age. The effects of the private water tanks were determined via field monitoring of real users and a mathematical model. This study demonstrates that the impact on apparent losses from the meter starting flow rapidly increases with meter age. Private water tanks, usually fed by a float valve, overstate meter under-registration, producing additional apparent losses between 15% and 40% for the users analysed in this study.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Criminisi et al. (2009) studied this question.

synapsesocial.com/papers/69dcc906a5c75be4cfe54625https://doi.org/10.2166/wst.2009.423
Ask AI
Helpful
Bookmark
Share
View Full Paper