PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 14, 2012Journal of Biomedical Materials Research Part B Applied Biomaterials258 citations

Stress shielding and fatigue limits of poly‐ether‐ether‐ketone dental implants

View Full Paper
WLWoo‐Taek LeeJKJai‐Young KoakYLYoung‐Jun Lim

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract The poly‐ether‐ether‐ketone (PEEK) polymer is of great interest as an alternative to titanium in orthopedics because of its biocompatibility and low elastic modulus. This study evaluated the fatigue limits of PEEK and the effects of the low elastic modulus PEEK in relation to existing dental implants. Compressive loading tests were performed with glass fiber‐reinforced PEEK (GFR‐PEEK), carbon fiber‐reinforced PEEK (CFR‐PEEK), and titanium rods. Among these tests, GFR‐PEEK fatigue tests were performed according to ISO 14801. For the finite element analysis, three‐dimensional models of dental implants and bone were constructed. The implants in the test groups were coated with a 0.5‐mm thick and 5‐mm long PEEK layer on the upper intrabony area. The strain energy densities (SED) were calculated, and the bone resorption was predicted. The fatigue limits of GFR‐PEEK were 310 N and were higher than the static compressive strength of GFR‐PEEK. The bone around PEEK‐coated implants showed higher levels of SED than the bone in direct contact with the implants, and the wider diameter and stiffer implants showed lower levels of SED. The compressive strength of the GFR‐PEEK and CFR‐PEEK implants ranged within the bite force of the anterior and posterior dentitions, respectively, and the PEEK implants showed adequate fatigue limits for replacing the anterior teeth. Dental implants with PEEK coatings and PEEK implants may reduce stress shielding effects. Dental implant application of PEEK polymer—fatigue limit and stress shielding. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2012

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lee et al. (2012) studied this question.

synapsesocial.com/papers/69dd3a2efb7610310c101279https://doi.org/10.1002/jbm.b.32669
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Characterization of short-fibre reinforced thermoplastics for fracture fixation devices1990 · 94 citations
  2. 2The long-term efficacy of currently used dental implants: a review and proposed criteria of success.1986 · 3,695 citations
  3. 3A finite element survey of eleven endosseous implants1990 · 92 citations
  4. 4Effects of mechanical forces on maintenance and adaptation of form in trabecular bone2000 · 1,186 citations
  5. 5Biting and Chewing in Overdentures, Full Dentures, and Natural Dentitions2000 · 821 citations