PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 7, 2015Journal of Cosmology and Astroparticle Physics413 citationsOpen Access

The effects of He I λ10830 on helium abundance determinations

EAErik AverKOKeith A. OliveESEvan D. Skillman

Key Points

Key points are not available for this paper at this time.

Abstract

Observations of helium and hydrogen emission lines from metal-poor extragalactic H II regions provide an independent method for determining the primordial helium abundance, Yₚ. Traditionally, the emission lines employed are in the visible wavelength range, and the number of suitable lines is limited. Furthermore, when using these lines, large systematic uncertainties in helium abundance determinations arise due to the degeneracy of physical parameters, such as temperature and density. Recently, Izotov, Thuan, & Guseva (2014) have pioneered adding the He 10830 infrared emission line in helium abundance determinations. The strong electron density dependence of He 10830 makes it ideal for better constraining density, potentially breaking the degeneracy with temperature. We revisit our analysis of the dataset published by Izotov, Thuan, & Stasinska (2007) and incorporate the newly available observations of He 10830 by scaling them using the observed-to-theoretical Paschen-gamma ratio. The solutions are better constrained, in particular for electron density, temperature, and the neutral hydrogen fraction, improving the model fit to data, with the result that more spectra now pass screening for quality and reliability, in addition to a standard 95% confidence level cut. Furthermore, the addition of He 10830 decreases the uncertainty on the helium abundance for all galaxies, with reductions in the uncertainty ranging from 10-80%. Overall, we find a reduction in the uncertainty on Yₚ by over 50%. From a regression to zero metallicity, we determine Yₚ = 0. 2449 +/- 0. 0040, consistent with the BBN result, Yₚ = 0. 2470 +/- 0. 0002, based on the Planck determination of the baryon density. The dramatic improvement in the uncertainty from incorporating He 10830 strongly supports the case for simultaneous (thus not requiring scaling) observations of visible and infrared helium emission line spectra.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Aver et al. (2015) studied this question.

synapsesocial.com/papers/69dd4d148557d5ab8f40cc13https://doi.org/10.1088/1475-7516/2015/07/011
Ask AI
Helpful
Bookmark
Share
View Full Paper