April 14, 2026JNCI Cancer Spectrum0 citationsOpen Access

Artificial intelligence-based multi-modal multi-tasks analysis of thyroid ultrasound image features predicts thyroid cancer: a multicenter study

View Full Paper
YGYu GuiXZXuerui ZhangYHYun He

Key Points

  • This research aims to assess the effectiveness of an AI system in enhancing the analysis of thyroid ultrasound images for cancer diagnosis.
  • Developed and validated the MDT-TC AI system using B-mode ultrasound images from 7204 lesions.
  • Conducted internal and external validations using multiple cohorts.
  • Analyzed the impact of key ultrasound features, such as echogenicity and shape, on model performance.
  • Achieved accuracy of up to 87.56% for echogenicity evaluation.
  • Showed sensitivity values of 98.7% for the internal validation cohort.
  • Demonstrated significantly higher AUC for radiologists assisted by MDT-TC compared to those without it.

Abstract

Abstract Thyroid nodule ultrasound (US) images and their features are of great importance in thyroid nodule diagnosis, and can be helpful for radiologists’ clinical decision-making. To evaluate whether an AI-assisted system can accurately characterize thyroid nodule ultrasound features and assist radiologists in diagnosing thyroid cancer. The AI-assisted system (MDT-TC) was trained and internally validated on B-mode US images from 7204 lesions in 6884 patients in Southwest Hospital (SW). The model performance was validated using three independent external validation cohorts. Echogenicity (ECH) and shape (SHA) are features of high importance for model recognition, and these features lead to excellent model performance. The model achieved up to 87.56% accuracy in determining ECH attributes and 69.21% in identifying shape categories. The AUC of the internal validation cohort and three independent external validation cohorts for MDT-TC were 0.951, 0.837, 0.816, and 0.871, respectively. The sensitivity values were 98.7%, 91.2%, 90.3%, and 85.6%, respectively. The AUC for the accurate diagnosis of radiologists with MDT-TC assistance was significantly higher than that of radiologists without MDT-TC assistance (p 0.001). In addition, the AUC for the accurate diagnosis of junior doctors with MDT-TC assistance was significantly higher than that for those who did not (p 0.01). MDT-TC incorporates radiomic features extracted from thyroid lesion US images, and can significantly improve the diagnostic performance of radiologists. This result was particularly strong for junior doctors. Therefore, our data support the idea that MDT-TC can help to identify patients with thyroid cancer and could greatly benefit clinical practice.